A divider has an upper and a lower resistor
In this circuit, R1 connects the ideal input source to the output node and R2 connects the output node to the reference node. Without an external load, the same current flows through R1 and R2. The output measured across R2 is Vin × R2 ÷ (R1 + R2). Reversing the resistor labels changes the fraction, so check the circuit orientation before entering values.
Choose one common unit for all resistor entries: ohms, kilohms or megohms. The calculator converts those values to ohms internally. Input and target output are in volts, while current and power rows use milliamps and milliwatts to make small divider currents readable.
Why a load changes the answer
A resistive load connected across the output is parallel with R2. The lower effective resistance is 1 ÷ (1/R2 + 1/Rload). Substitute this parallel resistance into the divider formula. Because it is smaller than R2 alone, an ordinary positive load lowers the output compared with the no-load value for the same pair of resistors.
The input current flows through R1, then splits between R2 and the load. The table reports all three currents, together with resistor and load power. It also shows the divider's ideal Thevenin output resistance with the ideal input source shorted: R1 parallel R2. This is not the resistance of a voltage-dependent or nonlinear load.
Example: a 12 V source and two 10 kΩ resistors
With no load, output is 6 V and input current is 0.6 mA. Connecting a 10 kΩ load makes the lower effective resistance 5 kΩ, so output becomes 12 × 5 ÷ 15 = 4 V. Input current rises to 0.8 mA, split into 0.4 mA through R2 and 0.4 mA through the load. Power in R1 is 6.4 mW; R2 and the load each dissipate 1.6 mW. The three powers total 9.6 mW, matching input voltage times input current.
Find R1 for a target voltage
Choose the design mode, enter R2 and any load, then set an output between zero and Vin. The exact upper resistance is the effective lower resistance multiplied by (Vin/Vtarget − 1). For 12 V to 3 V with a 10 kΩ lower resistor and no load, the result is 30 kΩ. The calculator does not round this answer to a preferred resistor series or hide the effect of the chosen load.
Real resistor tolerances, source impedance, leakage, ADC input behavior and temperature can change a circuit's output. Check the actual component data and select suitable ratings. A divider can be useful for signal scaling, but does not hold a supply voltage constant as a changing load draws current. Use the resistor calculator to examine preferred resistor values separately.
Frequently asked questions
Where does the load connect?
Across the output, in parallel with R2, not in series with the upper resistor.
Does finding R1 choose a standard resistor?
No. The result is the ideal exact resistance. A nearby available value changes the actual output.
Can this replace a voltage regulator?
No. Its output depends on loading and component values; it is a steady ideal DC calculation.
Last updated: November 14, 2026